SD-401 One host, One output device (single point)
SD-402 One host, Two output devices (dual point)

1. Sensor operation setting distance: (A) position 0.8 to 1.2mm, please press the setting switch and 199 to 0 will appear, and then move the sensor head iron block to adjust the operating distance to 80-120. (That is, 0.8mm to 1.2mm). After the setting is completed, you need to press the setting switch again to restore.
2. Operation of monitoring value setting: The precision setting range is ±1um-±99μm and the monitoring value is set according to the accuracy you actually need.
3. When the die starts to operate, the number displayed for the first four times of this inspection is the average value of the die height test. (This value will only be recalculated when the punch power switch is cut off "OFF" or the sensor line leaves the sensor and then reinserts the sensor, etc.).
4. SP: It will appear when the speed is abnormal and when it stops: another reason: it will appear when the upper and lower iron pieces suddenly fall off during the punching.
5. OP: Appears when the sensing wire and the sensing head are broken or the sensing wire is pulled apart.
6. HI: The abnormally high red light and the high yellow light will be on. (The distance exceeds 1.2mm or more)
7.LO: Too low abnormal red light and low red light will be on. (The distance exceeds 0.8mm or more)
8. ES: It will appear when there is an abnormality such as false delivery inspection, material missing inspection, and squeezing inspection.
9. When the power difference value display exceeds the set value, the abnormal light will be on.
10. This machine has a self-checking function.
11. The setting value of this machine is 1mm unit. Can be selected according to the needs of mold accuracy.
12. This inspection can be equipped with false delivery inspection, material out-of-material inspection (electric eye inspection), and squeeze inspection (sensing rod inspection).

Proper temperature 0-50℃
Weight
2.4kg
Output signal Relay contact (A.B) 250V3A
Voltage AC85V-250V50/60HZ±10%
Dimensions
105W×140H×185D

Number of sensors SD-401 one SD-402 two
Sensor size 30W×8H×20D
Sensor length 5cm-10cm
Cable length 3M and 5M two kinds
Measure the set distance 0.8mm-1.2mm
Maximum operating speed
2000S.P.M